Secure S1 class bomb shelters made of insulated concrete forms.

Ensure safety with BSF shelters.

Shelters, both above-ground and underground, have always played an important role in the protection of the civilian population. Proper S1-class shelters can be used in peacetime to store food, tools and other necessities, but in times of danger they are indispensable for survival. Both above-ground and underground shelters, BSF — Bomb Shelter Finland bomb shelters developed in Finland are a perfect choice, intended for use by both civilians and military personnel. A quality shelter is therefore an excellent addition to any real estate project.

Why should you build BSF bomb shelters?

Public shelters are often overcrowded or just scarce in some regions. A private shelter that is built to accommodate the right number of people in a time of need is a great solution for this issue. Not only does a private shelter offer a secure place for the residents of the building, but it also takes off some pressure from the public shelter facilities, providing value to the society as a whole. If every household had their own private shelter, public shelters and bunkers would be much safer as well.

BSF shelters are ideal just for this use case, being suitable for households, offices and military use due to well thought through sizing and equipment that follows the regulations and rules set for bomb shelters in Finland.

Specifications of our shelters

BSF Bomb Shelter Finland bomb shelters have been developed on the principle that they can be installed as quickly and safely as possible. The shelters are built using lightweight and efficient 302 mm concrete core thermal blocks, which means that the completed shelter is immediately insulated and ready for use even if a crisis should occur before the interior finishes are completed. The shelters have been developed based on the Finnish Regulation 408/2011 on Civil Defence Shelters.

Can be built both above ground and underground.

Thanks to the strong 302 mm thick insulated reinforced concrete walls, cast in one go as monolithic concrete without joints, and the 457 mm thick reinforced concrete ceiling, BSF shelters are safe even as above-ground structures.

Reinforced concrete walls, floor and roof meet the Finnish S1 requirement.

The walls and roof of an S1-class shelter must be made of reinforced concrete with a thickness of at least 300 mm and a floor of at least 200 mm, where the concrete is at least class C30/37 or higher and is properly vibro-compacted. The walls of BSF shelters exceed all minimum requirements to ensure maximum safety. The ceiling is cast on a Ruukki metal profile, which protects against possible concrete pieces and dust falling from the ceiling in the event of an impact.

Heavily reinforced walls for maximum strength.

BSF shelters have a double-layer 16 mm reinforcement mesh in the walls and ceiling. There are U-reinforcements in all corners. This ensures maximum strength for the shelter and a complete sense of security for the shelter user.

Can be built as a stand-alone shelter or connected to a building.

Our shelter can also be built under a new building or in the yard of an existing building. The civil defense shelter should be located no further than 500 meters from the building for which it is being built.

Shelters are available in different sizes.

BSF shelters are available in two basic sizes – L and XL, to provide shelter options for buildings with both larger and smaller space requirements. The actual shelter area for a public shelter must be at least 20 square meters, which is what both our L and XL shelters meet.

Pressure-resistant walls, doors and hatches, and ventilation.

The doors used in our shelters are designed and tested to withstand multiple long-term pressure loads and have a pressure resistance of 200 kPa (2 bar). Our ventilation system pressure valves have a pressure resistance of up to 300 kPa (3 bar).

These features ensure that it is a proper shelter that offers maximum protection to those taking shelter. Shelters that do not meet the minimum wall, ceiling and floor thicknesses, the correct concrete grade, or are not sufficiently reinforced cannot be called shelters – they are hiding places.

By special order, BSF shelters are also available with a door and accessories that meet S2 class requirements!

Check out our options

We offer various packages that include the right amount of building materials and the necessary doors, hatches and other essential accessories. We also offer various accessories and durable furniture suitable for basements and shelters. If you do not find a shelter that suits your needs among the available options, contact us and we will find a solution together.

BSF Shelter Finland is a B2B company and we do direct sales only to companies specializing in construction & real estate development and government organizations. If you are a private citizen and would like to have a BSF shelter built for your home, contact your local construction company with experience in shelter construction to receive an offer from us through them.

Our shelters can be shipped worldwide from our warehouses in Finland and Estonia.

Find your local BSF Shelters partner

No partners in your region yet? Become our authorized partner and work with us to bring durable and safe civil defence shelters to your country. Contact us for more information.